Description
GRP angles for fabrication, framing and edge details
GRP angles are L-shaped pultruded fibreglass profiles used for edging, framing, cleats, brackets, stops, guards, perimeter details and selected support arrangements where corrosion resistance, low weight or non-metallic construction is useful.
Choose an online configuration using the purchase controls above. Where a listed SKU has no confirmed online price, retain it as a quotation or technical-reference option until availability, resin and commercial data have been checked.
Live and quotation profile options
| Status | SKU | Profile | Wall | Length | Form / note |
|---|---|---|---|---|---|
| Online | PR-AN-50-40-06-GY-3M | 50 × 40 mm | 6 mm | 3 m | Unequal angle |
| Online | PR-AN-50-50-06-GY | 50 × 50 mm | 6 mm | 6 m | Equal angle |
| Online | PR-AN-75-75-10-GY | 75 × 75 mm | 10 mm | 6 m | Equal angle |
| Online | PR-AN-100-100-08-GY | 100 × 100 mm | 8 mm | 6 m | Equal angle |
| Online | PR-AN-100-100-10-GY | 100 × 100 mm | 10 mm | 6 m | Equal angle |
| Quote | PR-AN-50-40-06-GY | 50 × 40 mm | 6 mm | 6 m | Unequal; price/supply to confirm |
| Quote | PR-AN-76-76-06-PHEN | 76 × 76 mm | 6.35 mm | 5 m | Phenolic-coded; resin/performance to confirm |
| Quote | PR-AN-76-76-09-GY | 76 × 76 mm | 9.5 mm | 6 m | Price/supply to confirm |
How the dimensions are described
- A and B: the two leg dimensions. Equal angles use the same value; unequal angles use different values.
- t: nominal wall thickness for the confirmed profile.
- Length: supplied stock length before any agreed cutting or site preparation.
- Orientation: pultruded GRP is directionally reinforced; section orientation and connection details affect its use.
Delivery route for 3 m, 5 m and 6 m profiles
3 m online length
The priced 50 × 40 × 6 mm configuration can be selected online. Delivery charge and service depend on quantity and destination.
5 m quotation length
The 76 × 76 × 6.35 mm phenolic-coded SKU requires resin, performance, price and delivery confirmation before supply.
6 m long-length freight
Priced configurations can be selected online. Review access, unloading and postcode-dependent freight before ordering.
See Delivery and Collection for the current long-length route. Where shorter finished pieces would reduce site work or transport constraints, send a schedule through the cut-to-length profile service.
Material, pultrusion and directional behaviour
Pultrusion draws glass reinforcement and resin through a heated die to form a continuous L-shaped profile. Relevant confirmed products may be supplied against BS EN 13706 material-grade requirements, but the applicable grade, resin system and evidence must be checked for the selected SKU.
Material-property data does not create a universal safe load, unsupported span or connection capacity. Pultruded profiles are directionally reinforced, so loading across the profile, local holes, notches, end distances and restraint can govern the finished detail.
Typical structural and non-structural uses
- Edge trims, protective corners, stops and perimeter details.
- Cleats, brackets and fabricated frame components.
- Selected grating-bearing and support details where loading, bearing and connection design have been verified.
- Walkway, platform, plant-access and service-route fabrication.
- Equipment frames, cable-support details, guards and maintenance structures.
Wet, chemical, marine, electrical and exposed environments
GRP angles are often considered where corrosion, moisture, salt exposure, chemicals, outdoor weather or a non-metallic profile is useful. Final suitability depends on the confirmed resin, exposure concentration and temperature, UV requirements, fire-performance requirement, electrical specification, colour and fastener compatibility.
“Non-conductive” describes a relevant material characteristic; it is not by itself an approval for a particular electrical installation. Likewise, a phenolic-coded SKU requires its exact resin and performance evidence to be confirmed.
Cutting, drilling, fixing and edge finishing
- Use suitable composite cutting and drilling equipment with guards and dust extraction.
- Follow the applicable task assessment, PPE and respiratory-protection requirements.
- Confirm hole positions, diameter, spacing and minimum edge distance before drilling.
- Avoid unnecessary notches and abrupt changes that create local stress concentrations.
- Seal or finish cut edges where required by the product, environment or project procedure.
- Use fasteners compatible with the substrate, GRP profile and operating environment.
- Inspect the completed assembly before the access route, guard or equipment detail enters service.
Cut-to-length and project support
For repeated lengths, drilled details or drawing-led fabrication, send the exact SKU or profile geometry, finished lengths, quantities, tolerance, hole or notch information, edge-finishing requirement and delivery postcode. For mixed schedules and larger quantities, use the project quotation route.
Related structural-profile routes
Use the GRP Profiles hub to compare the full family, or the GRP Profile Guide when angle, channel, box section, tube or beam geometry still needs to be selected. For panel and profile connections, review GRP grating clips and fixings; fixing suitability depends on the actual interface.
GRP angle FAQs
Which GRP angles can I buy online?
The live selector currently contains five priced configurations: 50 × 40 × 6 mm in 3 m; 50 × 50 × 6 mm, 75 × 75 × 10 mm, 100 × 100 × 8 mm and 100 × 100 × 10 mm in 6 m. The selected variation price and availability message remain authoritative.
What happens to the other listed SKUs?
They remain valid catalogue records and are shown as quotation or technical-reference options. They have not been deleted; price, supply or resin information must be confirmed before purchase.
Can GRP angles be cut to finished lengths?
Yes. Send the SKU or complete section size, required lengths, quantities, tolerances and any drilling or finishing details through the cut-to-length route.
Can a GRP angle support grating?
Angle profiles may form part of selected bearing, cleat or perimeter details, but the clear span, load, bearing, orientation, restraint, fixing and substrate must be verified for the project.
Are all GRP angles electrically non-conductive and fire rated?
Do not rely on a generic catalogue statement. Confirm the selected product, test evidence, resin, condition of use and the project electrical or fire-performance requirement.











Reviews
There are no reviews yet.